1.
Arq. bras. oftalmol ; 80(5): 290-295, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888144

RESUMO

ABSTRACT Purpose: To evaluate the changes in several ocular parameters, including choroidal thickness, during and after hemodialysis. Methods: Twenty-seven eyes of 27 patients with chronic renal failure undergoing hemodialysis were included. The patients underwent an ophthalmic examination, including intraocular pressure, central corneal thickness, iridocorneal angle, subfoveal choroidal thickness, and blood pressure, just before a hemodialysis session, during the second hour of the session, and half an hour after the end of the session. Body weight was measured before and after the session, and ultrafiltration volume was noted after the session. Central corneal thickness, intraocular pressure, and subfoveal choroidal thickness were measured by optical coherence tomography. Results: In comparison with baseline levels, mean intraocular pressure and central corneal thickness increased significantly during the second hour of hemodialysis (p=0.001 and p=0.011, respectively) and showed no significant changes after hemodialysis (p=0.844 and p=0.246, respectively). Mean iridocorneal angle did not significantly change during the second hour of hemodialysis (p=0.101) and after hemodialysis (p=0.589). Mean subfoveal choroidal thickness was significantly lower during the second hour of hemodialysis (p<0.001) and after hemodialysis (p<0.001). Conclusions: Mean intraocular pressure and central corneal thickness increased and subfoveal choroidal thickness decreased during the second half of the hemodialysis session. During the second half of the session, intraocular pressure and central corneal thickness had a trend toward reduction, while subfoveal choroidal thickness had a relatively steady course. Because of possible fluctuations in the values, it would be reasonable to evaluate the changes not only from before to after hemodialysis but also during hemodialysis when analyzing the ocular effects of dialysis.


RESUMO Objetivo: Avaliar as alterações em vários parâmetros oculares, incluindo a espessura da coroide, durante e após a hemodiálise. Métodos: Foram incluídos 27 olhos de 27 pacientes portadores de insuficiência renal crônica e submetidos a hemodiálise. Todos foram submetidos ao exame oftalmológico, incluindo pressão intraocular, medida da espessura corneana central, ângulo iridocorneal e espessura da coroide subfoveal, além da medida da pressão arterial. A espessura corneana central, o ângulo iridocorneal e a espessura da coroide subfoveal foram medidos através da tomografia de coerência óptica. Os exames foram realizados logo antes, durante (na segunda hora) e meia hora após uma única sessão de hemodiálise. O peso corporal foi medido antes e depois da sessão, e os volumes de ultra filtração foram anotados após a sessão de hemodiálise. Resultados: Em comparação com os níveis basais, a pressão intraocular média e a espessura corneana central aumentaram significativamente na segunda hora de hemodiálise (p=0,001 e p=0,011, respectivamente), mas não houve diferença após a hemodiálise (p=0,844 para pressão intraocular e p=0,246 para espessura corneana central). O ângulo iridocorneal mostrou ligeira diminuição na segunda hora de hemodiálise (p=0,101) e após a sessão de hemodiálise (p=0,589), porém esta redução não foi estatisticamente significativa. Já a espessura da coroide subfoveal mostrou uma redução significativa tanto na segunda hora de hemodiálise (p<0,001) quanto após a sessão de hemodiálise (p<0,001). Conclusões: A pressão intraocular e a espessura corneana central aumentaram, enquanto a espessura da coroide subfoveal diminuiu na primeira metade da sessão de hemodiálise. Na segunda metade da sessão, a pressão intraocular e a espessura corneana central mostraram uma tendência de redução, enquanto a espessura da coroide subfoveal permaneceu estável. Ao analisar os efeitos oculares da hemodiálise, seria interessante avaliar as mudanças não só antes e depois da sessão, como também durante a hemodiálise, devido a possíveis flutuações dos valores.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Corioide/anatomia & histologia , Diálise Renal/efeitos adversos , Córnea/anatomia & histologia , Pressão Intraocular/fisiologia , Falência Renal Crônica/terapia , Retina/anatomia & histologia , Retina/fisiopatologia , Fatores de Tempo , Pressão Sanguínea/fisiologia , Peso Corporal , Corioide/fisiopatologia , Corioide/diagnóstico por imagem , Estatísticas não Paramétricas , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Paquimetria Corneana/métodos
2.
Arq. bras. oftalmol ; 79(4): 229-232, July-Aug. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-794575

RESUMO

ABSTRACT Purpose: To assess the effect of hemodialysis on retinal and choroidal thicknesses using spectral-domain optical coherence tomography (SD-OCT). Methods: In this prospective interventional study, 25 hemodialysis patients (17 male, 8 female) were enrolled. All participants underwent high-speed, high-resolution SD-OCT (λ=840 mm; 26.000 A-scans/s; 5 µm resolution) before and after hemodialysis. Choroidal thickness was measured perpendicularly from the outer edge of the retinal pigment epithelium to the choroid-sclera boundary at the fovea and at five additional points: 500 µm and 1000 µm nasal to the fovea and 500 µm, 1000 µm, and 1500 µm temporal to the fovea. Two masked physicians performed the measurements. Choroidal and retinal thicknesses before and after hemodialysis were compared. Results: The median choroidal thicknesses before and after hemodialysis were 182 µm (range, 103-374 µm) and 161 µm (range, 90-353 µm), respectively (P<0.001). The median retinal thicknesses were 246 µm (range, 179-296 µm) before and 248 µm (range, 141-299 µm) after hemodialysis (P>0.05). Systolic arterial pressure, diastolic arterial pressure, mean arterial pressure, heart rate, and ocular perfusion pressure significantly decreased after hemodialysis (P<0.001). Intraocular pressure did not vary significantly (P=0.540). Conclusion: Hemodialysis seems to cause a significant decrease in choroidal thickness, whereas it has no effect on retinal thickness. This significant decrease in choroidal thickness might be due to the extensive fluid absorption in hemodialysis, which could result in decreased ocular blood flow.


RESUMO Objetivo: Avaliar o efeito da hemodiálise (HD) na espessura da retina (RT) e na espessura da coroide (CT) usando tomografia de coerência óptica de domínio espectral (SD-OCT). Método: Neste estudo prospectivo intervencionista foram incluídos 25 pacientes em HD (17 homens e 8 mulheres). Todos os participantes foram submetidos a SD-OCT com dispositivo de alta resolução (λ=840 mm; 26.000 A-scans/seg e resolução de 5 µm), antes e após HD. A CT foi medida perpendicularmente a partir da borda externa do epitélio pigmentar da retina até o limite coroide-esclera na fóvea e em mais de 5 pontos localizados 500 µm nasal à fóvea, 1.000 µm nasal à fóvea; 500 µm temporal à fóvea, 1.000 µm temporal à fóvea, e 1.500 µm temporal à fóvea. Dois médicos realizaram as medidas sem o conhecimento do diagnóstico. Os dados da CT e RT, antes e após a HD foram comparados. Resultados: As CTs medianas antes e após a HD foram 182 µm (variação de 103-374 µm) e 161 µm (variação de 90-353 µm), respectivamente (p<0,001). A RT foi 246 µm (variação de 179-296 µm) antes e 248 µm (variação de 141-299 µm) após a HD (p>0,05). A pressão arterial sistólica, pressão arterial diastólica, as médias de pressão arterial média, frequência cardíaca e pressão de perfusão ocular diminuíram significativamente após HD (p<0,001). A pressão intraocular não alterou significativamente (p=0,540). Conclusão: A HD parece causar uma redução significativa da CT, e não ter efeito sobre a RT. Esta redução significativa da CT pode ser devida à grande absorção de fluido durante a HD, o que pode resultar numa diminuição do fluxo sanguíneo ocular.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Retina/anatomia & histologia , Retina/diagnóstico por imagem , Corioide/anatomia & histologia , Corioide/diagnóstico por imagem , Diálise Renal/efeitos adversos , Tamanho do Órgão , Valores de Referência , Retina/fisiopatologia , Fatores de Tempo , Variações Dependentes do Observador , Estudos Prospectivos , Corioide/fisiopatologia , Estatísticas não Paramétricas , Tomografia de Coerência Óptica/métodos , Olho/irrigação sanguínea , Hemodinâmica , Pressão Intraocular , Falência Renal Crônica/fisiopatologia , Falência Renal Crônica/terapia
3.
Arq. bras. endocrinol. metab ; 49(2): 217-227, abr. 2005.
Artigo em Português | LILACS | ID: lil-409728

RESUMO

A retinopatia é das complicacões mais comuns e está presente tanto no diabetes tipo 1 quanto no tipo 2, especialmente em pacientes com longo tempo de doenca e mau controle glicêmico. Quando culmina em perda visual é considerada trágica e constitui fator importante de morbidade de elevado impacto econômico, uma vez que a retinopatia diabética é a causa mais freqüente de cegueira adquirida. A fisiopatologia das alteracões microvasculares do tecido retiniano está relacionada à hiperglicemia crônica, que leva a alteracões circulatórias como a perda do tônus vascular, alteracão do fluxo sangüíneo, aumento da permeabilidade vascular e conseqüentemente extravasamentos e edemas e, por fim, obstrucão vascular que leva à neovascularizacão, com vasos frágeis que se rompem, levando a hemorragias e descolamento da retina. O controle metabólico e pressórico estritos podem retardar a progressão da retinopatia. Até o momento, nenhum agente farmacológico se mostrou eficaz em prevenir, retardar ou reverter a retinopatia diabética.O tratamento disponível no momento é a fotocoagulacão a laser de argônio e, em alguns casos, a vitrectomia. O sucesso do tratamento depende da deteccão precoce das lesões. Muitos estudos têm revelado mecanismos, assim como antagonistas importantes na evolucão da retinopatia.


Assuntos
Humanos , Retinopatia Diabética , Retinopatia Diabética/etiologia , Retinopatia Diabética/fisiopatologia , Retinopatia Diabética/terapia , Hiperglicemia/complicações , Retina/anatomia & histologia